76869 2005-02-11 | No information given | Cause: Power failure caused many of the processes to shut down. Followup: No Notes: | 17.0 pounds |
95360 2007-04-15 | Sox Scrubber Stack | Cause: see notes. the FCC gas expander triggered a shutdown of the FCC. The pressure in the unit discharged to the atmosphere via the Sox scrubber stack. Followup: No Notes: Letter sent to rescind notification concerning release of SO2 and PM. Cleared the valves of catalyst. Expander was restarted at a reduced rate. | 4.0 pounds |
103126 2008-02-17 | Flare | Cause: conducting functionality test for acid evacuation system. On of vent valves opened to flare. Followup: No Notes: Letter states that emissions were BRQ. | 3.0 pounds |
102953 2008-02-08 | No information given | Cause: pump seal failed on G8111 at the #2 Coker causing a fire Followup: No Notes: Letter states that emissions were BRQ. | |
123040 2010-04-27 | flare #1 | Cause: Compressor inadvertently tripped while executing Emergency Block Valve Prevention Maintenance Program procedure on it--sent material to flare. Followup: No Notes: Operations team secured the unit and started up the compressor, full evaluation and troubleshooting will be addressed during next shutdown. Will not perform EBV maintenance program in the meantime. |