Home Search Emissions Pollutants About the Database


Alon Refining (3116), Krotz Springs

LDEQ Accident Report

Accident #138331
State Police #12-01772
Accident Date2012-03-25
Report Date 2012-03-30
Follow-up Date 0000-00-00
Follow-up: No

Pollutants Released

Pollutant Duration Point Source Greenhouse Gas Criteria Pollutant Ozone forming chemical Amount of Release
Sulfur Dioxide30h 9mFLARE: FCCU flareNOYESNO797.0 pounds
Hexane30h 9mFLARE: FCCU flareNONONO319.5 pounds
Carbon Monoxide30h 9mFCCU regenerator stackNOYESNO2,463.6 pounds
Nitrogen Oxide30h 9mFCCU regenerator stackNOYESYES452.8 pounds
Volatile Organic Compounds (VOCs)30h 9mFCCU regenerator stackNONOYES5,144.0 pounds
Hydrogen Sulfide30h 9mFCCU regenerator stackNONONO31.6 pounds
Particulate Matter30h 9mFCCU regenerator stackNOYESNO30.1 pounds
Ethylene30h 9mFCCU regenerator stackNONOYES277.3 pounds
Propylene30h 9mFCCU regenerator stackNONOYES1,178.6 pounds

Accident Classified As: Reportable Quantity

Cause of Problem: Process Upset

A leak in a slurry pump caused a flash fire and triggered the shutdown of the FCCU and associated units. Safety reliefs vented to the FCC Unit flare.

Discharge Preventable - No Information Given

No Information Given.

Notes/Remedial Actions

The flash fire was extinguished. Safety devices functioned until units were fully down.