Home Search Emissions Pollutants About the Database


Motiva Enterprises (1406), Norco

LDEQ Accident Report

Accident #121572
State Police #10-00901
Accident Date2010-02-17
Report Date 2010-02-24
Follow-up Date 2010-04-07
Follow-up: Yes

Pollutants Released

Pollutant Duration Point Source Greenhouse Gas Criteria Pollutant Ozone forming chemical Amount of Release
1,3-Butadiene52h 25mFLARE - HCU Elevated Flare [EPN4-84], Relief Valve [RV1178 & RV1204]NONOYESBRQ
Benzene52h 25mFLARE - HCU Elevated Flare [EPN4-84], Relief Valve [RV1178 & RV1204]NONOYESBRQ
Butylene52h 25mFLARE - HCU Elevated Flare [EPN4-84], Relief Valve [RV1178 & RV1204]NONOYESBRQ
Flammable Gas52h 25mFLARE - HCU Elevated Flare [EPN4-84], Relief Valve [RV1178 & RV1204]NONOYESBRQ
Hexane52h 25mFLARE - HCU Elevated Flare [EPN4-84], Relief Valve [RV1178 & RV1204]NONONOBRQ
Propylene52h 25mFLARE - HCU Elevated Flare [EPN4-84], Relief Valve [RV1178 & RV1204]NONOYESBRQ
Volatile Organic Compounds (VOCs)52h 25mFLARE - HCU Elevated Flare [EPN4-84], Relief Valve [RV1178 & RV1204]NONOYESBRQ
Nitric Oxide52h 25mFLARE - HCU Elevated Flare [EPN4-84], Relief Valve [RV1178 & RV1204]NOYESNOBRQ

Accident Classified As:

Cause of Problem: Process Upset

Loss of electrical breaker powering most of the large motors in the hydrocracking unit caused two columns to "release to atmosphere;" RV-1178 on the Rectified Absorber Column for 30secs, RV-1204 on the Caustic Water Wash column "momentarily." FLARE.

Discharge Preventable - No Information Given

No information given.

Notes/Remedial Actions

BRQ. Refinery Follow-up Letter states "final calculations confirm that no reportable quantities were exceeded as a result of this release." Breaker loss discovered & repaired, operations returned to normal.