Home | Search | Emissions | Pollutants | About the Database |
LDEQ Accident Number Accident Date |
Point Source(s) | Notes | Amount of Release |
99302 2007-09-07 | Fresh acid line to Alkylation unit reactors | Cause: The fresh acid line to the Alkylation unit reactors developed a leak originating from a Furmanite manufactured box installed to control a prior leak. Followup: Yes Notes: Upon discovery of the leak, Furmanite was contacted and the manufactured box was re-pressurized and sealed. The leak was corrected and the line was returned to normal service duty. | 616.0 pounds |
126039 2010-08-31 | alky unit's tank L-431 | Cause: Alky unit's fresh sulfuric acid tank L-431 was leaking from a one inch flange on the north side. Followup: No Notes: BRQ. Refinery letter states that "final calculations confirm that no reportable quantities were exceeded." The fresh and spent acid tanks were equalized to reduce the pressure in the fresh acid tank L-431 to slow the leak rate. Bolts on the leaking flange was replaced, however that did not stop the leak. Therefore, a sealant material was pumped into the nozzle of the leaking flange and was wire wrapped in order to provide a permanent seal. No LDEQ report. Refinery letter only. | |
155529 2014-04-25 | Alkylation Unit | Cause: On 4/25/2014 the operators at Motiva's Alkylation Unit discovered the check valve of a transfer pump leaking sulfuric acid into the secondary containment. Followup: Yes Notes: The pump was immediately shut down to stop the leak. |