Home Search Emissions Pollutants About the Database


Motiva Enterprises (2719), Convent

Releases of Sewer Sludge

LDEQ Accident Number
Accident Date
Point Source(s) Notes Amount of Release
94481

2007-03-09
Drain hub at base of Flare 3
Cause: a plugged sewer line impeded proper drainage and caused the overflow of a drain hub

Followup: Yes

Notes: The following measures are being put in place to prevent a recurrence. 1) A secondary containment system is being installed around the drain hub; 2) The area surrounding the base of the flare is being graded to improve surface drainage; and 3) the operating procedure is being revised to include two (rather than one) operator while draining the flare tip molecular seal - one operator will operate the control valve while the other visually verifies proper drainage to the hub.
2,800.0 pounds