Home | Search | Emissions | Pollutants | About the Database |
Accident # | 103301 |
State Police # | No Information Given |
Accident Date | 2007-07-05 |
Report Date | 2007-09-11 |
Follow-up Date | 0000-00-00 |
Follow-up: | No |
Pollutant | Duration | Point Source | Greenhouse Gas | Criteria Pollutant | Ozone forming chemical | Amount of Release |
Sulfur Dioxide | 3 h 30 m | South Flare - EQT 080 | NO | YES | NO | 19,800.0 pounds |
Hydrogen Sulfide | 3 h 30 m | South Flare - EQT 080 | NO | NO | NO | 178.0 pounds |
Accident Classified As:
upset in the ARU
Level indicator on #2 regenerator tower malfunctioned and there isn't a redundant level indicator. Root Cause analysis estimates release at 19,800 lbs - approx 3,000 lbs more than original repor