Home Search Emissions Pollutants About the Database


Formosa Plastics (288), Baton Rouge

LDEQ Accident Report

Accident #99995
State Police #07-06014
Accident Date2007-10-05
Report Date 2010-03-26
Follow-up Date 0000-00-00
Follow-up: 

Pollutants Released

Pollutant Duration Point Source Greenhouse Gas Criteria Pollutant Ozone forming chemical Amount of Release
Vinyl Chloride12ma vesselNONONO5,815.0 pounds

Accident Classified As: No Information Given

Cause of Problem: Equipment Failure

Vinyl chloride release from venting of a vessel when DCM Control System was lost. Released 5815lb VCM from thermal overpressure of a PVC reactor. The power filter malfunction caused UPSto shut down and allowed monetary power interruption to DCS and triggered a manual shut down.

Discharge Preventable - No

Malfunction of the UPS power filter could not be anticipated.

Notes/Remedial Actions

Shut down the unit to secure the release. The reliability of power filters was tested extensively before putting them back into service. People will be trained to look for power failures of this nature.